Tuesday, 24 August 2010

Inspection Tutorial


Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Monday, 23 August 2010

Inspection Tutorial 1.


Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Wednesday, 18 August 2010

Inspection Tutorial 2.


Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Inspection Tutorial 3.



Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Inspection Tutorial 4.


Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Inspection Tutorial 5.


Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Inspection Tutorial 6.


Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Inspection Tutorial 7.


Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Inspection Tutorial 8.


Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Inspection Tutorial 9.



The pictures above were taken on a farm in a cattle shed.
Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Inspection Tutorial 10.


Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Inspection Tutorial 11.

Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.




Inspection Tutorial 12.

Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.


Tuesday, 17 August 2010

Inspection Tutorial 13.



Identify any deviations from BS 7671 in the above picture.
If applicable:-
Allocate a recommendation code C1, C2 or C3
as described on page 1&2 of the Electrical Installation Condition Report.
What would be your recommendation to achieve compliance with BS7671:2008.